Server room cooling prevents overheating, which can lead to hardware failures and unexpected system downtime. Ensuring maximum availability of the IT infrastructure guarantees uninterrupted functionality of IT systems.
Our Cooling Solutions for Server Rooms
Cools efficiently, saves energy, ensures availability
Prevent server failures with our cooling technology
Maximum Performance, Minimum Heat: Our Server Room Cooling Solutions
In the IT industry, chillers are used to cool data centers and other IT systems. They provide an efficient method for dissipating heat and maintaining optimal temperatures in server rooms. By deploying chillers in IT environments, efficient cooling, reduced energy consumption, and lower operational costs can be achieved. Moreover, they contribute to extending the lifespan of IT equipment by maintaining an optimal operating temperature and minimizing potential overheating issues.
Precise Temperature Control and Easy Installation
With over 20 years of experience in the development and manufacturing of refrigeration systems for industrial applications and process cooling, we are capable of keeping your equipment cool even under extreme conditions. Our industrial chiller units come as fully packaged units that can be easily installed and commissioned. The internal tank allows for precise chilled water temperature control within ±1°C to prevent temperature fluctuations regardless of the number of processes running. You can rely on us to provide reliable and customized solutions for any industrial process cooling application. Our chillers take the heat, so you don’t have to worry!
Optimal Server Room Cooling: Maximizing the Availability, Efficiency, and Security of Your IT Infrastructure
Ensure the efficient operation of your servers and the security of your data with our top-notch server room cooling solutions. We provide reliable and customized cooling solutions specifically designed for your unique requirements.
Our server room cooling offers a range of benefits:
- Maximum Availability: Our cooling systems ensure a constant temperature in your server room to minimize downtime due to overheating.
- Energy Efficiency: We employ energy-efficient technologies to optimize energy consumption and reduce operating costs.
- Environmental Responsibility: Our cooling solutions are environmentally friendly and contribute to reducing the ecological footprint.
- Precision Control: We offer precise temperature and humidity control to ensure the optimal performance of your servers and other IT equipment.
- Scalability: Our systems are scalable and adapt to your growing requirements.
- Professional Maintenance: Our team of experts is available to keep your cooling systems in top condition and minimize downtime.
Rely on our server room cooling to protect the integrity of your IT infrastructure and ensure that your systems are always available. Contact us today to learn more about our solutions and how they can benefit your business.
Are you interested in server room cooling solutions?
From planning to implementation and commissioning, we are your partner for energy-efficient cooling systems.
We are pleased to offer in-depth consultation to help you find the optimal solution for your requirements.
+49(0)2065-82948-0
Benefit from BAFA and KfW: Efficient Server Room Cooling with Attractive Funding!
Discover our state-of-the-art IT cooling systems, which not only provide top-notch cooling performance but also benefit from generous funding programs offered by BAFA and KfW. With support of up to 50% of the purchase price, the transition is now even more enticing. Reduce your operating costs, enhance efficiency, and make a statement for environmental conservation with chillers that meet your requirements while easing your budget. Make the switch now and reap the benefits!
Energy-Efficient Cooling for Server Rooms
Energy-efficient cooling of server rooms is crucial to optimize energy consumption, reduce costs, and enable more environmentally friendly operations. There are various approaches to achieve efficient cooling.
Efficient Airflow
By designing an optimized rack layout and utilizing perforated tiles or cold aisle enclosures, air can be evenly directed over the servers. This reduces hot spots and ensures effective heat dissipation, thereby reducing the cooling requirements.
Advanced Cooling Technology
The choice of the right cooling technology is also crucial. Advanced cooling equipment such as air-cooled or water-cooled chillers, indirect free cooling, or liquid cooling can provide more efficient and energy-saving solutions. These systems use innovative technologies to efficiently dissipate heat and minimize energy consumption.
Continuous Monitoring
The use of energy management systems and monitoring tools allows consumption data to be collected, analyzed, and potential energy savings to be identified. Regular maintenance of cooling equipment and cleaning of ventilation systems ensure optimal performance and prevent contaminants that could affect efficiency.
Enhanced Cooling Methods for Data Centers and Server Rooms
There are various methods to achieve efficient cooling for data centers and server rooms. These approaches aim to minimize energy consumption, reduce costs, and ensure effective cooling for server rooms.
CRAC (Computer Room Air Conditioning)
CRAC, which stands for “Computer Room Air Conditioning,” refers to a traditional method of cooling server rooms. In this approach, air conditioning units are used to blow cold air into the room. The chilled air is introduced through perforated tiles or ventilation grilles in the floor and then flows through the server racks to cool the equipment. Subsequently, the heated air is extracted from the hot rear sides of the racks and returned to the air conditioning unit, where it is cooled. This cycle continues to maintain consistent cooling.
Free cooling for server rooms
Free server room cooling, also referred to as “free cooling,” utilizes the natural coldness of the environment to cool server rooms instead of relying solely on air conditioning systems. This approach can be achieved by directly introducing outdoor air into the server room or by using heat exchangers to cool the outdoor air before it enters the room. Free cooling can be particularly efficient in regions with cold climates or during specific seasons when outdoor temperatures are low enough to cool the equipment without the need for additional air conditioning. This significantly reduces energy consumption and operating costs.
Cold aisle/hot aisle system
The cold aisle/hot aisle system is a method for optimizing airflow in server rooms. In this approach, server racks are arranged so that the front sides of the devices are located in a cold aisle where cool air is supplied, while the rear sides are located in a hot aisle. This reduces the mixing of warm and cold air and avoids hot spots. The cool air is directed specifically to the front sides of the servers where it cools the devices, and the heated air is efficiently expelled from the rear sides of the racks. This system helps optimize energy consumption because cooling is more targeted, requiring less air conditioning.
Sustainable Cooling Solutions for Server Rooms and Data Centers
Server Room Air Conditioning
Natural Air or Water Cooling
Data Center Air Conditioning
Air-Cooled Chiller Units
Highly efficient heat exchangers and modern compressor technologies enable energy-efficient operation of the chiller unit. These compact units are fully assembled at the factory, extensively tested, and find applications in various technical fields.
QBE
Liquid coolers with minimal dimensions, specially designed for process cooling, offering versatile configuration options.
Power range: 5 to 20 kW.
SARUS
Compact chillers with variable-speed reciprocating compressors for maximum energy efficiency even at partial loads.
Power range: 10 to 35 kW.
CERNA
Chillers specially designed as process coolers and expandable with a versatile range of options.
Power range: 20 to 120 kW.
RUBICON
Compact chilled water units with minimal space requirements for outdoor installation, optionally available with an internal circulation pump.
Power range: 40 to 100 kW
PADUS
Configurable chilled water units for a wide range of technical applications, offering maximum versatility and reliability.
Power range: 100 to 400 kW
TIGRIS
Liquid coolers for outdoor installation with scroll compressors and multiple refrigeration circuits for maximum operational safety.
Power range: 40 to 100 kW
Learn More in the Download Section
Extensive information, precise technical specifications, and up-to-date price lists for our high-quality chilled water units and innovative heat pumps are conveniently available in our download section. Here, you have access to comprehensive resources to fully acquaint yourself with our product range.
Request a quote or more information
(*) We need you to fill out these fields in order to be able to process your request as quickly as possible.
Can’t find the right product?
Or do you have any questions?
We’re here to help! Our team of refrigeration and air conditioning experts will be happy to help you choose your products! Just give us a call or send us an email.
We are here to help!
+49(0)2065-82948-0 Monday to Friday from 8 a.m. to 5 p.m |
|
info@bergcold.com Monday to Friday from 8 a.m. to 5 p.m |
|
+49(0)176-70760936 24h/day (no calls) |
We are here to help!
+49(0)2065-82948-0 Monday to Friday from 8 a.m. to 5 p.m |
|
info@bergcold.com Monday to Friday from 8 a.m. to 5 p.m |
|
+49(0)176-70760936 24h/day (no calls) |
Intercom DEEC GmbH
Dieselstraße 11
47228 Duisburg